<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>National Research Institute of Tuberculosis and Lung Disease (NRITLD), Shahid Beheshti University of Medical Sciences, Tehran, Iran</PublisherName>
				<JournalTitle>TANAFFOS (Respiration)</JournalTitle>
				<Issn>1735-0344</Issn>
				<Volume>21</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2022</Year>
					<Month>01</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Presentation of Two Simple Methods to Confirm Proper Tracheal Intubation: Palm Pressure, Plastic Bag Inflation, and Bag Pulsation</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>85</FirstPage>
			<LastPage>89</LastPage>
			<ELocationID EIdType="pii">254231</ELocationID>
			
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Zahid</FirstName>
					<LastName>Hussain Khan</LastName>
<Affiliation>Department of Anesthesiology, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-5017-6819</Identifier>

</Author>
<Author>
					<FirstName>Mojgan</FirstName>
					<LastName>Rahimi</LastName>
<Affiliation>Department of Anesthesiology, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Kamran</FirstName>
					<LastName>Mottaghi</LastName>
<Affiliation>Department of Anesthesiology, Shahid Beheshti University of Medical Sciences, Loghman Hakim Hospital, Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Masoud</FirstName>
					<LastName>Nashibi</LastName>
<Affiliation>Department of Anesthesiology, Shahid Beheshti University of Medical Sciences, Loghman Hakim Hospital, Tehran, Iran.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2022</Year>
					<Month>08</Month>
					<Day>23</Day>
				</PubDate>
			</History>
		<Abstract>&lt;strong&gt;Background: &lt;/strong&gt;The correct placement of the endotracheal tube is a cornerstone of safe anesthesia. Different methods, such as auscultation, capnography, and ultrasound, have their own limitations regarding the confirmation of endotracheal intubation, reinforcing the idea that a single technique is not foolproof. This study proposes a new technique in this regard.
&lt;strong&gt;Materials and Methods: &lt;/strong&gt;A total of 600 patients were enrolled in this study, and tracheal intubation was checked with palm pressure and disposable plastic glove inflation and pulsation.
&lt;strong&gt;Results: &lt;/strong&gt;The data were analyzed using the t-test and Mann-Whitney U test that indicate 94% and 94.8% sensitivity for palm pressure and bag pulsation, respectively, and a 100% positive predictive value for both tests.
&lt;strong&gt;Conclusion: &lt;/strong&gt;Palm pressure and bag pulsation are accurate, inexpensive, and reliable techniques to confirm proper tracheal intubation.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Tracheal intubation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Palm pressure</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Bag inflation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Bag pulsation</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.tanaffosjournal.ir/article_254231_9f5d219079f0db63172217de0b53d6e8.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
